Timer.Interval Egenskap
Definition
Viktigt
En del information gäller för förhandsversionen av en produkt och kan komma att ändras avsevärt innan produkten blir allmänt tillgänglig. Microsoft lämnar inga garantier, uttryckliga eller underförstådda, avseende informationen som visas här.
Hämtar eller anger intervallet, uttryckt i millisekunder, där händelsen ska höjas Elapsed .
public:
property double Interval { double get(); void set(double value); };
public double Interval { get; set; }
[System.Timers.TimersDescription("TimerInterval")]
public double Interval { get; set; }
[System.Timers.TimersDescription("TimerInterval")]
[System.ComponentModel.SettingsBindable(true)]
public double Interval { get; set; }
member this.Interval : double with get, set
[<System.Timers.TimersDescription("TimerInterval")>]
member this.Interval : double with get, set
[<System.Timers.TimersDescription("TimerInterval")>]
[<System.ComponentModel.SettingsBindable(true)>]
member this.Interval : double with get, set
Public Property Interval As Double
Egenskapsvärde
Tiden, i millisekunder, mellan Elapsed händelser. Värdet måste vara större än noll och mindre än eller lika med Int32.MaxValue. Standardvärdet är 100 millisekunder.
- Attribut
Undantag
Intervallet är mindre än eller lika med noll.
-eller-
Intervallet är större än Int32.MaxValue och timern är för närvarande aktiverad. (Om timern inte är aktiverad för tillfället utlöses inget undantag förrän den aktiveras.)
Exempel
I följande exempel instansierar ett Timer objekt som utlöser händelsen Timer.Elapsed varannan sekund (2 000 millisekunder), konfigurerar en händelsehanterare för händelsen och startar timern. Händelsehanteraren visar värdet för egenskapen varje gång den ElapsedEventArgs.SignalTime utlöses.
using System;
using System.Timers;
public class Example
{
private static Timer aTimer;
public static void Main()
{
// Create a timer and set a two second interval.
aTimer = new System.Timers.Timer();
aTimer.Interval = 2000;
// Hook up the Elapsed event for the timer.
aTimer.Elapsed += OnTimedEvent;
// Have the timer fire repeated events (true is the default)
aTimer.AutoReset = true;
// Start the timer
aTimer.Enabled = true;
Console.WriteLine("Press the Enter key to exit the program at any time... ");
Console.ReadLine();
}
private static void OnTimedEvent(Object source, System.Timers.ElapsedEventArgs e)
{
Console.WriteLine("The Elapsed event was raised at {0}", e.SignalTime);
}
}
// The example displays output like the following:
// Press the Enter key to exit the program at any time...
// The Elapsed event was raised at 5/20/2015 8:48:58 PM
// The Elapsed event was raised at 5/20/2015 8:49:00 PM
// The Elapsed event was raised at 5/20/2015 8:49:02 PM
// The Elapsed event was raised at 5/20/2015 8:49:04 PM
// The Elapsed event was raised at 5/20/2015 8:49:06 PM
open System.Timers
let onTimedEvent source (e: ElapsedEventArgs) =
printfn $"The Elapsed event was raised at {e.SignalTime}"
// Create a timer and set a two second interval.
let aTimer = new Timer()
aTimer.Interval <- 2000
// Hook up the Elapsed event for the timer.
aTimer.Elapsed.AddHandler onTimedEvent
// Have the timer fire repeated events (true is the default)
aTimer.AutoReset <- true
// Start the timer
aTimer.Enabled <- true
printfn "Press the Enter key to exit the program at any time... "
stdin.ReadLine() |> ignore
// The example displays output like the following:
// Press the Enter key to exit the program at any time...
// The Elapsed event was raised at 5/20/2015 8:48:58 PM
// The Elapsed event was raised at 5/20/2015 8:49:00 PM
// The Elapsed event was raised at 5/20/2015 8:49:02 PM
// The Elapsed event was raised at 5/20/2015 8:49:04 PM
// The Elapsed event was raised at 5/20/2015 8:49:06 PM
Imports System.Timers
Public Module Example
Private aTimer As Timer
Public Sub Main()
' Create a timer and set a two second interval.
aTimer = New System.Timers.Timer()
aTimer.Interval = 2000
' Hook up the Elapsed event for the timer.
AddHandler aTimer.Elapsed, AddressOf OnTimedEvent
' Have the timer fire repeated events (true is the default)
aTimer.AutoReset = True
' Start the timer
aTimer.Enabled = True
Console.WriteLine("Press the Enter key to exit the program at any time... ")
Console.ReadLine()
End Sub
Private Sub OnTimedEvent(source As Object, e As System.Timers.ElapsedEventArgs)
Console.WriteLine("The Elapsed event was raised at {0}", e.SignalTime)
End Sub
End Module
' The example displays output like the following:
' Press the Enter key to exit the program at any time...
' The Elapsed event was raised at 5/20/2015 8:48:58 PM
' The Elapsed event was raised at 5/20/2015 8:49:00 PM
' The Elapsed event was raised at 5/20/2015 8:49:02 PM
' The Elapsed event was raised at 5/20/2015 8:49:04 PM
' The Elapsed event was raised at 5/20/2015 8:49:06 PM
Kommentarer
Du använder egenskapen Interval för att fastställa hur ofta händelsen Elapsed utlöses. Timer Eftersom klassen är beroende av systemklockan har den samma upplösning som systemklockan. Det innebär att Elapsed händelsen utlöses med ett intervall som definieras av systemklockans upplösning om Interval egenskapen är mindre än systemklockans upplösning. I följande exempel anges Interval egenskapen till 5 millisekunder. När den körs på ett Windows system vars systemklocka har en upplösning på cirka 15 millisekunder utlöses händelsen ungefär var 15:e millisekunder i stället för var 5:e millisekunder.
Note
Systemklockan som används är samma klocka som används av GetTickCount, som inte påverkas av ändringar som gjorts med timeBeginPeriod och timeEndPeriod.
using System;
using System.IO;
using System.Collections.Generic;
using System.Timers;
public class Example
{
private static Timer aTimer;
private static List<String> eventlog;
private static int nEventsFired = 0;
private static DateTime previousTime;
public static void Main()
{
eventlog = new List<String>();
StreamWriter sr = new StreamWriter(@".\Interval.txt");
// Create a timer with a five millisecond interval.
aTimer = new Timer(5);
aTimer.Elapsed += OnTimedEvent;
// Hook up the Elapsed event for the timer.
aTimer.AutoReset = true;
sr.WriteLine("The timer should fire every {0} milliseconds.",
aTimer.Interval);
aTimer.Enabled = true;
Console.WriteLine("Press the Enter key to exit the program... ");
Console.ReadLine();
foreach (var item in eventlog)
sr.WriteLine(item);
sr.Close();
Console.WriteLine("Terminating the application...");
}
private static void OnTimedEvent(Object source, ElapsedEventArgs e)
{
eventlog.Add(String.Format("Elapsed event at {0:HH':'mm':'ss.ffffff} ({1})",
e.SignalTime,
nEventsFired++ == 0 ?
0.0 : (e.SignalTime - previousTime).TotalMilliseconds));
previousTime = e.SignalTime;
if (nEventsFired == 20) {
Console.WriteLine("No more events will fire...");
aTimer.Enabled = false;
}
}
}
// The example writes output like the following to a file:
// The timer should fire every 5 milliseconds.
// Elapsed event at 08:42:49.370344 (0)
// Elapsed event at 08:42:49.385345 (15.0015)
// Elapsed event at 08:42:49.400347 (15.0015)
// Elapsed event at 08:42:49.415348 (15.0015)
// Elapsed event at 08:42:49.430350 (15.0015)
// Elapsed event at 08:42:49.445351 (15.0015)
// Elapsed event at 08:42:49.465353 (20.002)
// Elapsed event at 08:42:49.480355 (15.0015)
// Elapsed event at 08:42:49.495356 (15.0015)
// Elapsed event at 08:42:49.510358 (15.0015)
// Elapsed event at 08:42:49.525359 (15.0015)
// Elapsed event at 08:42:49.540361 (15.0015)
// Elapsed event at 08:42:49.555362 (15.0015)
// Elapsed event at 08:42:49.570364 (15.0015)
// Elapsed event at 08:42:49.585365 (15.0015)
// Elapsed event at 08:42:49.605367 (20.002)
// Elapsed event at 08:42:49.620369 (15.0015)
// Elapsed event at 08:42:49.635370 (15.0015)
// Elapsed event at 08:42:49.650372 (15.0015)
// Elapsed event at 08:42:49.665373 (15.0015)
open System
open System.IO
open System.Timers
let aTimer = new Timer 5
let eventlog = ResizeArray()
let mutable nEventsFired = 0
let mutable previousTime = DateTime()
let onTimedEvent source (e: ElapsedEventArgs) =
String.Format("Elapsed event at {0:HH':'mm':'ss.ffffff} ({1})", e.SignalTime, if nEventsFired = 0 then 0. else (e.SignalTime - previousTime).TotalMilliseconds)
|> eventlog.Add
nEventsFired <- nEventsFired + 1
previousTime <- e.SignalTime
if nEventsFired = 20 then
printfn "No more events will fire..."
aTimer.Enabled <- false
[<EntryPoint>]
let main _ =
use sr = new StreamWriter(@".\Interval.txt")
// Create a timer with a five millisecond interval.
aTimer.Elapsed.AddHandler onTimedEvent
// Hook up the Elapsed event for the timer.
aTimer.AutoReset <- true
sr.WriteLine $"The timer should fire every {aTimer.Interval} milliseconds."
aTimer.Enabled <- true
printfn "Press the Enter key to exit the program... "
stdin.ReadLine() |> ignore
for item in eventlog do
sr.WriteLine item
printfn "Terminating the application..."
0
// The example writes output like the following to a file:
// The timer should fire every 5 milliseconds.
// Elapsed event at 08:42:49.370344 (0)
// Elapsed event at 08:42:49.385345 (15.0015)
// Elapsed event at 08:42:49.400347 (15.0015)
// Elapsed event at 08:42:49.415348 (15.0015)
// Elapsed event at 08:42:49.430350 (15.0015)
// Elapsed event at 08:42:49.445351 (15.0015)
// Elapsed event at 08:42:49.465353 (20.002)
// Elapsed event at 08:42:49.480355 (15.0015)
// Elapsed event at 08:42:49.495356 (15.0015)
// Elapsed event at 08:42:49.510358 (15.0015)
// Elapsed event at 08:42:49.525359 (15.0015)
// Elapsed event at 08:42:49.540361 (15.0015)
// Elapsed event at 08:42:49.555362 (15.0015)
// Elapsed event at 08:42:49.570364 (15.0015)
// Elapsed event at 08:42:49.585365 (15.0015)
// Elapsed event at 08:42:49.605367 (20.002)
// Elapsed event at 08:42:49.620369 (15.0015)
// Elapsed event at 08:42:49.635370 (15.0015)
// Elapsed event at 08:42:49.650372 (15.0015)
// Elapsed event at 08:42:49.665373 (15.0015)
Imports System.Collections.Generic
Imports System.IO
Imports System.Timers
Module Example
Private WithEvents aTimer As Timer
Private eventlog As List(Of String)
Private nEventsFired As Integer = 0
Private previousTime As Date
Public Sub Main()
eventlog = New List(Of String)()
Dim sr As New StreamWriter(".\Interval.txt")
' Create a timer with a five millisecond interval.
aTimer = New Timer(5)
aTimer.AutoReset = True
sr.WriteLine("The timer should fire every {0} milliseconds.",
aTimer.Interval)
aTimer.Enabled = True
Console.WriteLine("Press the Enter key to exit the program... ")
Console.ReadLine()
For Each item In eventlog
sr.WriteLine(item)
Next
sr.Close()
Console.WriteLine("Terminating the application...")
End Sub
Private Sub OnTimedEvent(source As Object, e As ElapsedEventArgs) _
Handles aTimer.Elapsed
eventlog.Add(String.Format("Elapsed event at {0:HH':'mm':'ss.ffffff} ({1})",
e.SignalTime,
If(nEventsFired = 0,
0.0, (e.SignalTime - previousTime).TotalMilliseconds)))
nEventsFired += 1
previousTime = e.SignalTime
if nEventsFired = 20 Then
Console.WriteLine("No more events will fire...")
aTimer.Enabled = False
End If
End Sub
End Module
' The example displays the following output:
' The timer should fire every 5 milliseconds.
' Elapsed event at 08:42:49.370344 (0)
' Elapsed event at 08:42:49.385345 (15.0015)
' Elapsed event at 08:42:49.400347 (15.0015)
' Elapsed event at 08:42:49.415348 (15.0015)
' Elapsed event at 08:42:49.430350 (15.0015)
' Elapsed event at 08:42:49.445351 (15.0015)
' Elapsed event at 08:42:49.465353 (20.002)
' Elapsed event at 08:42:49.480355 (15.0015)
' Elapsed event at 08:42:49.495356 (15.0015)
' Elapsed event at 08:42:49.510358 (15.0015)
' Elapsed event at 08:42:49.525359 (15.0015)
' Elapsed event at 08:42:49.540361 (15.0015)
' Elapsed event at 08:42:49.555362 (15.0015)
' Elapsed event at 08:42:49.570364 (15.0015)
' Elapsed event at 08:42:49.585365 (15.0015)
' Elapsed event at 08:42:49.605367 (20.002)
' Elapsed event at 08:42:49.620369 (15.0015)
' Elapsed event at 08:42:49.635370 (15.0015)
' Elapsed event at 08:42:49.650372 (15.0015)
' Elapsed event at 08:42:49.665373 (15.0015)
Om din app kräver större upplösning än den Timer som erbjuds av klassen eller systemklockan använder du multimedietimers med hög upplösning. Mer information finns i Så här använder du High-Resolution Timer.
Om intervallet anges när har Timer startats återställs antalet. Om du till exempel anger intervallet till 5 sekunder och sedan anger Enabled egenskapen till truebörjar antalet vid den tidpunkt Enabled som anges. Om du återställer intervallet till 10 sekunder när antalet är 3 sekunder aktiveras Elapsed händelsen för första gången 13 sekunder efter Enabled att den har angetts till true.
Om Enabled är inställt på true och AutoReset är inställt på false, Timer genererar Elapsed händelsen bara en gång, första gången intervallet förflutit.
Enabled är sedan inställt på false.
Note
Om Enabled och AutoReset båda är inställda på false, och timern tidigare har aktiverats, orsakar Interval inställningen Elapsed av egenskapen att händelsen aktiveras en gång, som om Enabled egenskapen hade angetts till true. Om du vill ange intervallet utan att höja händelsen kan du tillfälligt ange Enabled egenskapen till true, ange Interval egenskapen till önskat tidsintervall och sedan omedelbart ställa in Enabled egenskapen på false.