HtmlInputCheckBox.ServerChange Gebeurtenis

Definitie

Treedt op wanneer de webpagina wordt verzonden naar de server en de status van het HtmlInputCheckBox besturingselement wordt gewijzigd vanaf het vorige bericht.

public:
 event EventHandler ^ ServerChange;
public event EventHandler ServerChange;
member this.ServerChange : EventHandler 
Public Custom Event ServerChange As EventHandler 

Gebeurtenistype

Voorbeelden

In het volgende codevoorbeeld ziet u hoe u een handler voor de ServerChange gebeurtenis opgeeft en codeeert.

<%@ Page Language="C#" AutoEventWireup="True" %>

<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
    "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" >
<head>
    <title>HtmlInputCheckBox Sample</title>
<script language="C#" runat="server">

      void Button1_Click(object sender, EventArgs e) 
      { 

         if (Prev_Check_State.Value == Check1.Checked.ToString())
            Span2.InnerHtml = "CheckBox1 did not change state between clicks.";

         if (Check1.Checked)
         {          
            Span1.InnerHtml = "CheckBox1 is selected!";
            Prev_Check_State.Value="True";
         }         
         else
         { 
            Span1.InnerHtml = "CheckBox1 is not selected!";
            Prev_Check_State.Value="False";
         }
         
      }

      void Server_Changed(object sender, EventArgs e) 
      {
         Span2.InnerHtml = "CheckBox1 changed state between clicks.";
      }

   </script>

</head>

<body>

   <h3>HtmlInputCheckBox Sample</h3>

   <form id="form1" runat="server">

      <input id="Check1" 
             type="checkbox"
             onserverchange="Server_Changed" 
             runat="server"/> 
 
      CheckBox1   

      <span id="Span1" 
            style="color:red" 
            runat="server"/>

      <br />

      <input type="button" 
             id="Button1" 
             value="Enter" 
             onserverclick="Button1_Click" 
             runat="server"/>
      
      <br /><br />

      <span id="Span2" 
            runat="server"/>

      <input type="hidden" id="Prev_Check_State"
                       visible="false"
                       runat="server"/>

   </form>

</body>
</html>
<%@ Page Language="VB" AutoEventWireup="True" %>

<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
    "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" >
<head>
    <title>HtmlInputCheckBox Sample</title>
<script language="VB" runat="server">

    Sub Button1_Click(sender As Object, e As EventArgs)
        
        If Prev_Check_State.Value = Check1.Checked.ToString() Then
            Span2.InnerHtml = "CheckBox1 did not change state between clicks."
        End If
        If Check1.Checked = True Then
            Span1.InnerHtml = "CheckBox1 is selected!"
            Prev_Check_State.Value = "True"
        Else
            Span1.InnerHtml = "CheckBox1 is not selected!"
            Prev_Check_State.Value = "False"
        End If
    End Sub 'Button1_Click
     

    Sub Server_Changed(sender As Object, e As EventArgs)
        Span2.InnerHtml = "CheckBox1 changed state between clicks."
    End Sub 'Server_Changed

  </script>

</head>

<body>

   <h3>HtmlInputCheckBox Sample</h3>

   <form id="form1" runat="server">

      <input id="Check1" 
             type="checkbox"
             onserverchange="Server_Changed" 
             runat="server"/> 
 
      CheckBox1   

      <span id="Span1" 
            style="color:red" 
            runat="server"/>

      <br />

      <input type="button" 
             id="Button1" 
             value="Enter" 
             onserverclick="Button1_Click" 
             runat="server"/>
      
      <br /><br />

      <span id="Span2" 
            runat="server"/>

      <input type="hidden" id="Prev_Check_State"
                       visible="false"
                       runat="server"/>
   </form>

</body>
</html>

Opmerkingen

Deze gebeurtenis wordt gegenereerd wanneer de webpagina wordt verzonden naar de server en de status van het HtmlInputCheckBox besturingselement wordt gewijzigd vanaf het vorige bericht.

Note

Het besturingselement moet de weergavestatus hebben ingeschakeld om de ServerChange gebeurtenis correct te laten werken.

Zie Gebeurtenissen verwerken en genereren voor meer informatie over het afhandelen van gebeurtenissen.

Van toepassing op

Zie ook